  • myself248 3 hours ago ago

    Ooooo, and it supports secondary addressing? NONE of the low-cost interfaces support secondary addressing! (At least last time I looked around!)

    That's a big deal for those of us with R&S CMU200's / CRTU's, which require secondary addressing to make it act like a spec-an with tracking generator. And I see that in your list of tested equipment!

    Fantastic. And the price of prebuilt units is super reasonable. I'm in.

  • georgeburdell 3 hours ago ago

    Great work making this available for sale. NI and Keysight are the only two traditional vendors of this kind of thing and they’re priced close to $1k these days. There are tons of knock-offs on Ebay that won’t last more than a few months if they ever work.

    • ycui1986 an hour ago ago

      used NI-GPIB on USB cost $100 on ebay. You don’t need $1000.

  • puzzlingcaptcha 5 hours ago ago

    I wish AVR DU series had any sort of open source support, we could finally move on from 32U4.

    https://www.microchip.com/en-us/products/microcontrollers/8-...

  • xyphro 7 hours ago ago

    You are correct. UsbTmc exposes no multi device capability. Also when I made first versions many years ago I had no "garden hose" GPIB cables and saw they were more expensive as the whole adapter. V3 which will come early next year supports GPIB daisy chaining/multi device support via Ethernet VXI11 & HiSlip. The V2 adapter shown here supports trigger, SRQ, serial poll, trigger, clear, local lockout, goto lockal, pulse indicator, all features though. If you absolutely need common synchronous trigger to a chain of GPIB instruments which is quite seldomly absolutely required, you'll have it in next version V3.

  • Retr0id 7 hours ago ago

    Interesting. I built an AR488 a while back (https://github.com/Twilight-Logic/AR488) and it worked alright for my needs. I'd be interested to see a comparison of the two projects.

    • xyphro 7 hours ago ago
      • Retr0id 7 hours ago ago

        Ooh! The faster speeds would be very welcome, I was bothered by the slowness of the AR488 but I assumed that was just how GPIB was (I had no baseline to compare to). I'll switch over when I get a chance.

        That user's project also looks very interesting - My TDS684A's CRT seems to have died, and rather than fix it I could switch to using a software scope.

        • xyphro 6 hours ago ago

          The upcoming V3 adapter reaches even more than 1 MByte/s with my fastest instruments. Unless you connect long GPIB cables to it, because capacitive load slows down GPIB as it self regulates speed down in the way GPIB is designed.

  • labcomputer 8 hours ago ago

    Am I wrong in understanding that each physical device supports only a single GPIB device at a time? The enumeration and discovery scheme is certainly novel, but one device per hardware would seem to prevent using some of GPIB’s advanced features like parallel polling and low latency triggers.

  • sansseriff 11 hours ago ago

    Glad to see there's a REV 3 in progress that would support ethernet. That's the one thing that would make me go out of my way to build one of these.

  • nine_k 10 hours ago ago

    Isn't this a better link? https://github.com/xyphro/UsbGpib/blob/9a8c18a7be1b17127496e...

    At least it renders the Markdown.

  • ChrisMarshallNY 6 hours ago ago

    I cut my teeth on IEE-488. I didn’t realize that it was still a thing.

    • 0xTJ 2 hours ago ago

      I finished my Master's a couple years ago, and in our IC probing lab, it was almost all GPIB. All of the pieces of test equipment, except for a single cutting-edge Keysight scope (which used Ethernet instead), were connected together via those chunky but satisfying and robust cables, usually controlled via MATLAB or some other IC measurement software package.

    • schobi 3 hours ago ago

      Linux mainline kernel just had support for GPIB added. https://hackaday.com/2025/12/16/after-decades-linux-finally-...

    • georgeburdell 3 hours ago ago

      There’s a fairly large second-hand market for old electronics test equipment. A lot of that stuff only had GPIB ports, even well into the 90s. Cheap Chinese entrants (Rigol, Siglent, etc.) only within the last decade started making an impact

  • YakBizzarro 8 hours ago ago

    Maybe someonw can explain me, but I never understood the appeal of GPIB for modern instruments (legacy instruments are of course "excused"). Electrically is a terrible interface that introduces ground loops with the control computer. Speed are laughable and it requires exensive and exotic adapters with complex sw stack (I wish this projects good success, it's needed!). Ethernet in comparison tick all my boxes. It's electrically decoupled by default (just use UTP cables), crazy cheap, very fast and with sane sw stack thanks to vxi-11. You can even bypass visa if you wish and open a plain TCP socket, no need for any library. What am I missing?

    • labcomputer 5 hours ago ago

      > What am I missing?

      Not much, but consider latency: You can use the Group Execute Trigger (GET) to simultaneously trigger multiple instruments with both very low latency and very low latency dispersion. Think, easy-to-use sub-microsecond synchronization.

      Ethernet and USB 4 may have orders of magnitude more bandwidth, but can’t achieve the same multi-device synchronization capability without side channel signals.

      Now, sure, you can add the same capability with a programmable pulse generator connected via coax to the trigger input of all your instruments, but GBIP lets you do that with just the data connection (and you don’t always have a spare trigger channel). The only other protocols I know of with similar capabilities are PXI and PXIe, which are “PCI(express) in an incompatible form-factor, plus some extra signals for real time synchronization”.

      • rowanG077 2 hours ago ago

        sub-microsecond triggering should be doable with a level-2 cut-through switch and an ethernet broadcast no? I admit that ethernet is not really designed for that as the Phy is then the latency bottleneck.

    • xyphro 6 hours ago ago

      If you buy used equipment which doesn't have Ethernet or your company wants you to ise the stuff that is in the Lab since 10+ years there's simply no other choice. Or companies that see Ethernet as a potential security attack vector. It's indeed not that GPIB is better than Ethernet. In tiny aspects that's argueable, but as general statement true.

      • myself248 3 hours ago ago

        > Or companies that see Ethernet as a potential security attack vector.

        It's sad how true this is. VXI gets corporate IT all prickly. An airgapped lab network would be safer but somehow they hate that idea even more.

        GPIB isn't even on their radar. Test to your heart's content. It's not a "network".

    • sokoloff 6 hours ago ago

      Nothing, other than perhaps just much high-quality legacy equipment is out in the field that still works fantastically.

  • ycui1986 10 hours ago ago

    very impressive. better than anything on the market either NI or Keysight.

  • bsder 7 hours ago ago

    I strongly suspect that this does not meet the strict timing requirements that GPIB has. Putting this on your bus is likely to violate both the T1 hard timing requirements and the impedance requirements.

    Use of the "standard" set of 74-series buffers that everybody uses would meet impedance requirements and would also allow the usage of a much faster MCU which likely could be made to adhere to the strict T1 timing requirements (with the caveat that most microcontroller USB stacks are piles of garbage that demand that they get interrupt priority even when you tell them otherwise).

    • xyphro 5 hours ago ago

      For a situation where the instrument is directly connected to the adapter like here there is no difficulty in fast T1 timing on a MCU. V3 will have btw. fully compliant GPIB electrical specs without 74 series buffers. 48mA drivers are not required for a direct connection scenario as V2 supports. VIH is a bit violated, though not practically meaningful. So far I heard of no device not working after over 6 years and those who did not in early stages I managed to get running with sw updates. This is not a one shot plain textbook GPIB simple thing implementation, it's years of iterations, debug, improvement.